{"product_id":"compression-sleeve-puller","title":"Compression Sleeve Puller — Pulls a Stuck 1\/2 in Ferrule Off Copper Without Cutting the Pipe","description":"\u003cdiv style=\"max-width:1080px;margin:0 auto;color:#1E2532;line-height:1.7\"\u003e\n\n\u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eChanging a shut-off valve\u003c\/p\u003e\n\u003ch2 style=\"font-size:34px;line-height:1.25;font-weight:600;margin:0 0 16px\"\u003eThe old ferrule will not slide off. This pulls it.\u003c\/h2\u003e\n\u003cp style=\"font-size:17px;max-width:800px;margin:0 0 20px\"\u003eA compression fitting works by squeezing a brass ring onto the copper. Once it has been tightened, that ring is swaged on — it will not come off over the end of the pipe, and neither will the nut behind it. So the usual answer is to cut the stub-out back, and then you are working with even less pipe than before. This tool seats inside the old fitting, takes the nut onto its own thread, and draws the whole lot straight off with a few turns of the T-handle.\u003c\/p\u003e\n\u003cdiv style=\"background:#1E2532;color:#fff;border-radius:14px;padding:24px 28px;margin:0 0 24px\"\u003e\n  \u003cp style=\"margin:0 0 8px;font-weight:600;font-size:17px\"\u003eRead this first: it is a \u003cstrong style=\"color:#fff\"\u003e1\/2 in\u003c\/strong\u003e tool, and it pulls, it does not cut.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 10px;color:#D8DCE2\"\u003eThis size fits the \u003cstrong style=\"color:#fff\"\u003e1\/2 in nominal compression fitting\u003c\/strong\u003e — the one on the inlet side of a standard angle stop, where the valve meets the copper coming out of the wall. It is \u003cstrong style=\"color:#fff\"\u003enot\u003c\/strong\u003e for the 3\/8 in outlet that the faucet riser screws onto, and not for PEX, CPVC or flare fittings.\u003c\/p\u003e\n  \u003cp style=\"margin:0;color:#D8DCE2\"\u003eAnd the ring it pulls is \u003cstrong style=\"color:#fff\"\u003escrap once it is off\u003c\/strong\u003e. That is normal — you fit a new nut and a new ferrule with the new valve. Nobody reuses a swaged ring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/2170\/2490\/files\/S1b5acd9f006447ab93ca388e8a4c3144H_a4a76e1a-f214-4c7a-8528-99d04f320c30.webp\" alt=\"The compression sleeve puller: a T-handle screw with a threaded body and a collet nose\" style=\"width:100%;max-width:700px;border-radius:14px;display:block;margin:0 auto 22px\"\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:14px;margin:0 0 52px\"\u003e\n  \u003cdiv style=\"flex:1 1 200px;background:#F4F5F6;border-radius:12px;padding:18px 20px\"\u003e\n\u003cp style=\"margin:0 0 4px;font-weight:600\"\u003eNo cutting\u003c\/p\u003e\n\u003cp style=\"margin:0;font-size:14px;color:#5A6472\"\u003eThe stub-out keeps its length\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"flex:1 1 200px;background:#F4F5F6;border-radius:12px;padding:18px 20px\"\u003e\n\u003cp style=\"margin:0 0 4px;font-weight:600\"\u003e1\/2 in fittings\u003c\/p\u003e\n\u003cp style=\"margin:0;font-size:14px;color:#5A6472\"\u003eThe inlet side of an angle stop\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"flex:1 1 200px;background:#F4F5F6;border-radius:12px;padding:18px 20px\"\u003e\n\u003cp style=\"margin:0 0 4px;font-weight:600\"\u003e16.9 cm long\u003c\/p\u003e\n\u003cp style=\"margin:0;font-size:14px;color:#5A6472\"\u003e6.65 in, with a 4 in T-handle\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"flex:1 1 200px;background:#F4F5F6;border-radius:12px;padding:18px 20px\"\u003e\n\u003cp style=\"margin:0 0 4px;font-weight:600\"\u003eSingles or packs\u003c\/p\u003e\n\u003cp style=\"margin:0;font-size:14px;color:#5A6472\"\u003eOne, two or three\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:36px;align-items:center;margin:0 0 52px\"\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/2170\/2490\/files\/Scc120c2bb76f47fe95a7e2cb51aeb19bJ.webp\" alt=\"Four steps: remove the old fitting, seat the nose in the collar, thread the nut on, turn the handle\" style=\"width:100%;border-radius:14px;display:block\"\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eHow it works\u003c\/p\u003e\n    \u003ch2 style=\"font-size:28px;line-height:1.3;font-weight:600;margin:0 0 14px\"\u003eFour turns, not a hacksaw\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px\"\u003e\u003cstrong\u003e1.\u003c\/strong\u003e Water off, valve opened to drain, old stop unscrewed and pulled clear — the nut and the ring stay behind on the copper. \u003cstrong\u003e2.\u003c\/strong\u003e Push the silver nose of the puller into the mouth of the pipe, right inside the old ferrule.\u003c\/p\u003e\n    \u003cp style=\"margin:0\"\u003e\u003cstrong\u003e3.\u003c\/strong\u003e Run the old compression nut back onto the puller’s own threaded body, hand-tight against it. \u003cstrong\u003e4.\u003c\/strong\u003e Hold the body and turn the T-handle clockwise. The screw pushes against the pipe, the body pulls the nut, and the ring walks off the end. A few turns is all it takes.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:36px;align-items:center;flex-direction:row-reverse;margin:0 0 52px\"\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/2170\/2490\/files\/Sadf3b0163a3d4a6f84953d4cbbc822864_1523f297-4eb6-405c-a5b6-fd3e9563eb7b.webp\" alt=\"The ferrule and nut coming off a copper stub-out in the wall, undamaged\" style=\"width:100%;border-radius:14px;display:block\"\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eWhat it saves\u003c\/p\u003e\n    \u003ch2 style=\"font-size:28px;line-height:1.3;font-weight:600;margin:0 0 14px\"\u003eThe inch of pipe you cannot get back\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px\"\u003eCut the stub-out to get rid of a stuck ferrule and you lose length every time. On a pipe that came out of the wall short to begin with — behind a vanity, under a kitchen sink, against a finished tile wall — two of those cuts and there is nothing left to clamp a new fitting onto. Then it is opening the wall, or a coupling and a stub extension.\u003c\/p\u003e\n    \u003cp style=\"margin:0\"\u003eThe escutcheon matters too. Cut back and the new stop sits deeper, so the trim plate no longer covers the hole. Pulling the ring leaves the pipe exactly where the plumber left it.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:36px;align-items:center;margin:0 0 52px\"\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/2170\/2490\/files\/S1d890335e46c470da7b48bd9f8a4dc3fI.webp\" alt=\"Before and after: a corroded compression ring removed without cutting the pipe\" style=\"width:100%;border-radius:14px;display:block\"\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eOld and seized\u003c\/p\u003e\n    \u003ch2 style=\"font-size:28px;line-height:1.3;font-weight:600;margin:0 0 14px\"\u003eThe ones that have been on twenty years\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px\"\u003eA valve that has never been turned tends to come with a nut welded in place by corrosion and hard water. Those are exactly the ones worth pulling rather than cutting, because they are usually in the worst position to get a saw into.\u003c\/p\u003e\n    \u003cp style=\"margin:0\"\u003eBe honest with yourself about the limit, though: if the nut will not even start onto the puller’s thread, or the screw is taking real force and nothing has moved, stop. Some fittings are past it, and a cut is the safe answer — better that than a kinked stub-out and a wet floor.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:36px;align-items:center;flex-direction:row-reverse;margin:0 0 52px\"\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/2170\/2490\/files\/nexura-ferrule-pack3.jpg\" alt=\"Three compression sleeve pullers, the 3-pack\" style=\"width:100%;border-radius:14px;display:block\"\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eOne, two or three\u003c\/p\u003e\n    \u003ch2 style=\"font-size:28px;line-height:1.3;font-weight:600;margin:0 0 14px\"\u003eMost people need one\u003c\/h2\u003e\n    \u003cp style=\"margin:0 0 14px\"\u003eWe will say that plainly: for a single valve, or the two under a bathroom sink, \u003cstrong\u003eone puller\u003c\/strong\u003e is the whole job. Buy the single.\u003c\/p\u003e\n    \u003cp style=\"margin:0\"\u003eThe \u003cstrong\u003e2\u003c\/strong\u003e and \u003cstrong\u003e3\u003c\/strong\u003e packs are for the cases where one is not enough — a plumber putting one in each van, a crew re-stopping a whole building, a landlord going through a block of units, or anyone who has learned that the way these tools die is a stripped thread on a nut that was never going to move. Then a spare in the box beats a second trip.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#F4F5F6;border-radius:14px;padding:30px 28px;margin:0 0 52px\"\u003e\n  \u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eStraight answers\u003c\/p\u003e\n  \u003ch2 style=\"font-size:26px;line-height:1.3;font-weight:600;margin:0 0 14px\"\u003eWhat it will not do\u003c\/h2\u003e\n  \u003cp style=\"margin:0 0 14px\"\u003e\u003cstrong\u003eOne size, and it is 1\/2 in.\u003c\/strong\u003e There is no 3\/8 in version in this listing, and 3\/8 in is what most faucet and toilet risers use on the outlet side of the stop. Check which end you are working on before you order.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 14px\"\u003e\u003cstrong\u003eIt does not save the ferrule.\u003c\/strong\u003e The ring comes off deformed and the nut is usually chewed. Buy a new nut and sleeve, or a new valve that ships with them — they cost almost nothing and a reused ring is a leak waiting for you.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 14px\"\u003e\u003cstrong\u003eIt needs pipe to work with.\u003c\/strong\u003e The nose has to go into the end of the stub-out and the nut has to reach the puller’s thread. A pipe cut flush with the wall, or one that is bent, out of round or split at the end, gives it nothing to hold.\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 14px\"\u003e\u003cstrong\u003eCopper, not plastic.\u003c\/strong\u003e A CPVC or PEX stub-out with a compression stop on it is a different job. So is a flare fitting, a sweated fitting and a push-fit — a push-fit comes off with a release clip, not a puller.\u003c\/p\u003e\n  \u003cp style=\"margin:0\"\u003e\u003cstrong\u003eThere is no published pulling force or steel spec.\u003c\/strong\u003e The maker gives none and we will not invent one. It is a zinc-plated steel body with a chromed T-bar; treat it as a hand tool, turn it by hand, and do not put a bar on the handle.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:36px;align-items:center;margin:0 0 52px\"\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cdiv style=\"background:#1E2532;color:#fff;border-radius:14px;padding:26px 28px\"\u003e\n      \u003cp style=\"color:#F3A26D;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eBefore you start\u003c\/p\u003e\n      \u003cp style=\"margin:0 0 10px;color:#D8DCE2\"\u003e\u003cstrong style=\"color:#fff\"\u003eWater off at the main, not just at the stop\u003c\/strong\u003e — the stop is the thing you have decided you do not trust. Open a low faucet to drain the line and keep a towel and a bowl under the work.\u003c\/p\u003e\n      \u003cp style=\"margin:0 0 10px;color:#D8DCE2\"\u003e\u003cstrong style=\"color:#fff\"\u003eSupport the pipe.\u003c\/strong\u003e Hold the stub-out steady with your other hand or a wrench while you turn. A stub-out that twists in the wall can break a soldered joint you cannot see, and that leak will be inside the wall.\u003c\/p\u003e\n      \u003cp style=\"margin:0;color:#D8DCE2\"\u003e\u003cstrong style=\"color:#fff\"\u003eTurn the water back on slowly\u003c\/strong\u003e and watch the joint for a few minutes, then check again an hour later. If your building needs a licensed plumber for this work, it still does.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1 1 340px\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/2170\/2490\/files\/S1b803199260a4961a3307ad0b624f082h.webp\" alt=\"Used on corroded and seized fittings under a sink, behind a toilet and at a dishwasher\" style=\"width:100%;border-radius:14px;display:block\"\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eThe specifics\u003c\/p\u003e\n\u003ch2 style=\"font-size:28px;line-height:1.3;font-weight:600;margin:0 0 16px\"\u003eWhat you get\u003c\/h2\u003e\n\u003cdiv style=\"border-top:1px solid #E3E6EA;margin:0 0 52px;max-width:820px\"\u003e\n  \u003cdiv style=\"display:flex;gap:20px;border-bottom:1px solid #E3E6EA;padding:12px 0\"\u003e\n\u003cdiv style=\"flex:0 0 190px;color:#5A6472\"\u003eFits\u003c\/div\u003e\n\u003cdiv style=\"flex:1\"\u003e1\/2 in nominal compression fittings on copper — the inlet side of a standard angle stop\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"display:flex;gap:20px;border-bottom:1px solid #E3E6EA;padding:12px 0\"\u003e\n\u003cdiv style=\"flex:0 0 190px;color:#5A6472\"\u003eDoes not fit\u003c\/div\u003e\n\u003cdiv style=\"flex:1\"\u003e3\/8 in compression, flare, sweat, push-fit, PEX and CPVC\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"display:flex;gap:20px;border-bottom:1px solid #E3E6EA;padding:12px 0\"\u003e\n\u003cdiv style=\"flex:0 0 190px;color:#5A6472\"\u003eLength\u003c\/div\u003e\n\u003cdiv style=\"flex:1\"\u003e16.89 cm (6.65 in) overall\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"display:flex;gap:20px;border-bottom:1px solid #E3E6EA;padding:12px 0\"\u003e\n\u003cdiv style=\"flex:0 0 190px;color:#5A6472\"\u003eT-handle\u003c\/div\u003e\n\u003cdiv style=\"flex:1\"\u003e10.16 cm (4 in) across, sliding bar\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"display:flex;gap:20px;border-bottom:1px solid #E3E6EA;padding:12px 0\"\u003e\n\u003cdiv style=\"flex:0 0 190px;color:#5A6472\"\u003eBuild\u003c\/div\u003e\n\u003cdiv style=\"flex:1\"\u003eZinc-plated steel body and screw, chromed T-bar, steel nose\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"display:flex;gap:20px;border-bottom:1px solid #E3E6EA;padding:12px 0\"\u003e\n\u003cdiv style=\"flex:0 0 190px;color:#5A6472\"\u003ePacks\u003c\/div\u003e\n\u003cdiv style=\"flex:1\"\u003eOne, two or three pullers — identical tool, just the count\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"display:flex;gap:20px;border-bottom:1px solid #E3E6EA;padding:12px 0\"\u003e\n\u003cdiv style=\"flex:0 0 190px;color:#5A6472\"\u003eNot included\u003c\/div\u003e\n\u003cdiv style=\"flex:1\"\u003eReplacement nuts and ferrules, the new valve, and thread tape\u003c\/div\u003e\n\u003c\/div\u003e\n  \u003cdiv style=\"display:flex;gap:20px;border-bottom:1px solid #E3E6EA;padding:12px 0\"\u003e\n\u003cdiv style=\"flex:0 0 190px;color:#5A6472\"\u003eNot published\u003c\/div\u003e\n\u003cdiv style=\"flex:1\"\u003eA pulling-force rating, the steel grade and the thread spec — the maker gives none, so we quote none\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eQuestions people ask\u003c\/p\u003e\n\u003ch2 style=\"font-size:28px;line-height:1.3;font-weight:600;margin:0 0 8px\"\u003eBefore you order\u003c\/h2\u003e\n\u003cdiv style=\"margin:0 0 44px\"\u003e\n  \u003cdetails style=\"border-bottom:1px solid #E3E6EA;padding:14px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;font-size:16px\"\u003eIs my fitting 1\/2 in or 3\/8 in?\u003c\/summary\u003e\u003cp style=\"margin:12px 0 0\"\u003eLook at which end you are fighting. The pipe coming out of the wall into the valve is almost always 1\/2 in nominal copper — that is this tool. The small chrome or braided line running up to the faucet or toilet is 3\/8 in, on the other end of the same valve. If you are pulling a ring off the wall pipe, you want 1\/2 in.\u003c\/p\u003e\u003c\/details\u003e\n  \u003cdetails style=\"border-bottom:1px solid #E3E6EA;padding:14px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;font-size:16px\"\u003eCan I reuse the nut and ring?\u003c\/summary\u003e\u003cp style=\"margin:12px 0 0\"\u003eNo. The ring is deformed by design and the nut has been dragged over a thread it was never meant to meet. New nut, new sleeve — most new angle stops come with both.\u003c\/p\u003e\u003c\/details\u003e\n  \u003cdetails style=\"border-bottom:1px solid #E3E6EA;padding:14px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;font-size:16px\"\u003eWill it damage the copper?\u003c\/summary\u003e\u003cp style=\"margin:12px 0 0\"\u003eUsed as intended, no — that is the whole point of it. It goes wrong when the nose is not seated properly inside the pipe, or when the stub-out is left to twist while you turn. Seat it, hold the pipe, go steadily.\u003c\/p\u003e\u003c\/details\u003e\n  \u003cdetails style=\"border-bottom:1px solid #E3E6EA;padding:14px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;font-size:16px\"\u003eWhat if it will not budge?\u003c\/summary\u003e\u003cp style=\"margin:12px 0 0\"\u003eBack it off and look. Often the nut is not square on the thread, or there is grit behind the ring. If the screw is taking serious force and nothing has moved, cut the pipe instead — forcing it risks the joint inside the wall, which is a much worse afternoon.\u003c\/p\u003e\u003c\/details\u003e\n  \u003cdetails style=\"border-bottom:1px solid #E3E6EA;padding:14px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;font-size:16px\"\u003eDoes it work on a stub-out that is very short?\u003c\/summary\u003e\u003cp style=\"margin:12px 0 0\"\u003eIt needs enough pipe for the nose to go in and for the old nut to reach the puller’s thread. If the copper barely clears the escutcheon you may not have that, and a short stub is also the case where cutting hurts most — worth measuring first.\u003c\/p\u003e\u003c\/details\u003e\n  \u003cdetails style=\"border-bottom:1px solid #E3E6EA;padding:14px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;font-size:16px\"\u003eWhy would I buy two or three?\u003c\/summary\u003e\u003cp style=\"margin:12px 0 0\"\u003eYou probably would not. One does a house. The packs are for trade buyers who want one in every van or on every job box, and for anyone re-stopping a building where a lost or stripped tool means a second trip.\u003c\/p\u003e\u003c\/details\u003e\n  \u003cdetails style=\"border-bottom:1px solid #E3E6EA;padding:14px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;font-size:16px\"\u003eIs a puller better than just cutting the pipe?\u003c\/summary\u003e\u003cp style=\"margin:12px 0 0\"\u003eWhere you have plenty of stub-out and easy access, cutting is quicker. Where the pipe is short, boxed in, tiled around or already cut once, pulling is the only way to keep the fitting where it is. That is when this earns its place in the bag.\u003c\/p\u003e\u003c\/details\u003e\n  \u003cdetails style=\"border-bottom:1px solid #E3E6EA;padding:14px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;font-size:16px\"\u003eDo I need any other tools?\u003c\/summary\u003e\u003cp style=\"margin:12px 0 0\"\u003eAn adjustable wrench for the old nut, a towel and a bowl, and the new valve with its nut and sleeve. Nothing else.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#F4F5F6;border-radius:14px;padding:30px 28px;margin:0 0 24px\"\u003e\n  \u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 10px\"\u003eShipping \u0026amp; returns\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 10px\"\u003e\u003cstrong\u003eDelivery in 7–15 business days\u003c\/strong\u003e from the time you order — that window already includes the 1–2 business days we take to process. Tracking is emailed as soon as the carrier scans the parcel. \u003ca href=\"\/pages\/shipping-delivery\" style=\"color:#E5622A\"\u003eShipping \u0026amp; Delivery\u003c\/a\u003e.\u003c\/p\u003e\n  \u003cp style=\"margin:0\"\u003e\u003cstrong\u003e30-day returns.\u003c\/strong\u003e Items must be unused and in their original packaging. Email \u003ca href=\"mailto:support@nexuratool.com\" style=\"color:#E5622A\"\u003esupport@nexuratool.com\u003c\/a\u003e to start a return.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align:center;padding:26px 0 6px\"\u003e\n\u003cp style=\"color:#E5622A;font-size:12px;letter-spacing:.18em;text-transform:uppercase;font-weight:700;margin:0 0 8px\"\u003eNexura Tools\u003c\/p\u003e\n\u003cp style=\"margin:0;max-width:620px;display:inline-block;font-size:15px;color:#5A6472\"\u003eTools for repair, maintenance and the jobs in between — chosen for specs we can verify.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n","brand":"Nexura Tools","offers":[{"title":"1 piece","offer_id":44894697586778,"sku":"NX-FERRULE-1","price":29.95,"currency_code":"USD","in_stock":true},{"title":"2 pieces","offer_id":44894748344410,"sku":"NX-FERRULE-2","price":50.95,"currency_code":"USD","in_stock":true},{"title":"3 pieces","offer_id":44894748377178,"sku":"NX-FERRULE-3","price":74.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/2170\/2490\/files\/S1b5acd9f006447ab93ca388e8a4c3144H_a4a76e1a-f214-4c7a-8528-99d04f320c30.webp?v=1790178942","url":"https:\/\/nexuratool.com\/products\/compression-sleeve-puller","provider":"Nexura Tools","version":"1.0","type":"link"}